4 Manual — Proceq Profometer
: Location, structure type, and specific area tested (e.g., "Bridge Pier #4 North Face"). Instrument Settings : Crucial for the Profometer 4. Document the selected bar diameter
—making it ideal for quality control and acceptance inspections. Multiple Scanning Modes: Single-Line Mode:
Scan in two orthogonal directions. Map out the top layer completely before attempting to interpret deeper signals. Take readings in the center of mesh squares to minimize background interference when looking for deeper structural bars. Highly Magnetic Aggregates
While newer models (like the Profometer 600 series) have since been released, the Profometer 4 remains in active use globally. proceq profometer 4 manual
Operating the Profometer 4 requires a systematic approach to isolate magnetic interference and achieve true readings. Step 1: Pre-Operational Calibration and Zeroing
: The unit calculates the depth of the concrete covering based on the signal strength. Diameter Estimation
Ensure the probe cable connectors remain dry and free of concrete dust. Battery Management : Location, structure type, and specific area tested (e
Once the data is in PM-Link, the software allows you to create customized reports. You can choose between various data views (single line, multiple lines, area scan, statistics, etc.), and export the results in formats like CSV or HTML for use in third-party applications or for sharing with stakeholders.
The Profometer 4 (and its successor, the 5+) operates on the . It induces a magnetic field in the concrete; when a metallic object like a reinforcing bar is encountered, it creates an "echo" that the device measures to determine depth and position.
A: Yes, Appendix D covers the optional "Profometer 4 Wheel Probe" for rapid scanning. It requires recalibration of distance per revolution. Multiple Scanning Modes: Single-Line Mode: Scan in two
Use the spot probe; angle the scan diagonal to the upper mesh layer. Internal self-test failure or probe disconnection.
The official manual mandates a full factory calibration every 12 months. However, the built-in "Air Calibration" should be done at the start of every workday.