Long press the SET button for 5 seconds to save and exit. Parameters Defined UP (Upper Limit): High voltage threshold. dn (Lower Limit): Low voltage threshold.
| Parameter | Meaning | Example Setting (12V Lead‑Acid) | | :-------- | :------------------------------ | :------------------------------- | | | Upper voltage limit (overcharge protection) | 14.4 V (charging stop) | | dn | Lower voltage limit (over‑discharge protection) | 10.5 V (load disconnect) | | OP | Maximum on‑time (minutes:seconds). Set 00:00 to disable. | 01:30 | | dOP | Delay‑on time (seconds) before restarting after a cycle completes | 030 (30 seconds) | | FOP | Discharge mode only . Forces relay ON for 0–10 seconds to stabilise load | 003 (3 seconds) |
The is a versatile digital battery charging and discharging controller module designed to manage battery health by preventing overcharging and over-discharging . It is commonly used in DIY electronics, solar power setups, and battery maintenance systems. Core Functionality
DC 6V - 60V (Suitable for 12V, 24V, 36V, 48V systems).
LCD screen showing voltage, percentage (calculated as xycd60 manual
If you encounter issues with the Xycd60, refer to the following troubleshooting guide:
To install and set up the Xycd60:
Set IN Mode, UP = 14.4V (Stop charging), dn = 12.0V (Start charging).
Forced turn-on time for discharge mode (0-10 seconds) [as per Scribd User Manual]. Save Settings: Long press the SET button for ≈is approximately equal to 5 seconds to save parameters and exit. 5. Wiring and Connections Long press the SET button for 5 seconds to save and exit
Prevents overcharging. When the battery voltage drops to a user-set lower limit ( dn ), the relay closes to begin charging. Once it hits the upper limit ( UP ), the relay opens to stop.
To develop a comprehensive paper on the XY-CD60 Battery Charging and Discharging Controller
Short press or long press the UP/DOWN buttons to increase or decrease the parameter values.
The battery’s voltage is below 6 V, above 60 V, or the battery type is incompatible. | Parameter | Meaning | Example Setting (12V
Used to prevent overcharging. The relay connects the charger to the battery when the voltage drops to the lower limit ( dn ) and disconnects once it reaches the upper limit ( UP ).
: The relay may "click" rapidly if the charging current is too high or the battery capacity is too small, causing the voltage to bounce between limits. 3. Operational Features LCD Display : Shows real-time voltage and settings.
A: This is usually due to voltage fluctuations at the threshold. Increase the difference between your UP and dn settings to create a larger hysterisis band.
Comprehensive Guide to the XY-CD60 Battery Charge/Discharge Controller Module